圖片僅供參考
MAXM86161EFD+T
SENSOR OPTICAL I2C OUTPUT
- 製造商
- 製造商。 部分 #MAXM86161EFD+T
- 包
- 資料表
- 有現貨的3554
100%原創; 新
24小時準備發貨
365天保修
RFQ&; 獲得更多折扣
規格
| Part Status | Active |
| Sensor Type | Optical |
| Output Type | I2C |
| Operating Temperature | -40°C ~ 85°C |
| Base Product Number | MAXM86161 |
概述
Description
The MAXM86161EFD+T is a compact, low-power optical sensor module designed for non-invasive photoplethysmography (PPG) and heart rate monitoring applications. It is part of Maxim Integrated's lineup, now under Analog Devices. The module integrates a photodetector, an analog front-end, and a microcontroller, which simplifies design and reduces space in wearable health and fitness devices.
Key features include low power consumption to extend battery life, high sampling rates, and exceptional ambient light rejection to ensure accurate readings under various lighting conditions. The MAXM86161EFD+T supports multiple wavelengths, typically green, red, and infrared, allowing it to measure oxygen saturation (SpO2), heart rate, and other biometric data.
It comes in a compact package, making it suitable for applications like smartwatches, fitness bands, and other portable health devices. Its digital output simplifies integration with microcontrollers and other digital systems. The module's design focuses on providing precise and reliable measurements, even in challenging environments, enabling developers to create advanced health monitoring solutions efficiently.
Key features include low power consumption to extend battery life, high sampling rates, and exceptional ambient light rejection to ensure accurate readings under various lighting conditions. The MAXM86161EFD+T supports multiple wavelengths, typically green, red, and infrared, allowing it to measure oxygen saturation (SpO2), heart rate, and other biometric data.
It comes in a compact package, making it suitable for applications like smartwatches, fitness bands, and other portable health devices. Its digital output simplifies integration with microcontrollers and other digital systems. The module's design focuses on providing precise and reliable measurements, even in challenging environments, enabling developers to create advanced health monitoring solutions efficiently.
Features
The MAXM86161EFD+T is a compact, complete optical data-acquisition system for heart-rate and SpO2 monitoring applications. Key features include:
1. Integrated Module: Combines photodetectors, LEDs, and an optical AFE, reducing the need for additional components.
2. Ultra-Low Power: Optimized for low power consumption to extend battery life in wearable devices.
3. High Sensitivity: Offers high signal-to-noise ratio for accurate readings even in low-light conditions.
4. Compact Size: Its small form factor is ideal for space-constrained applications such as fitness trackers and smartwatches.
5. Flexible Operation: Programmable sample rates and LED current settings for customized configurations.
6. I²C Interface: Enables easy communication with microcontrollers and other digital systems.
7. Ambient Light Cancellation: Reduces noise from external light sources, enhancing accuracy.
8. Multiple Applications: Suitable for wrist, finger, or ear-based measurement devices.
These features make the MAXM86161EFD+T a versatile solution for health monitoring in various wearable technology applications.
1. Integrated Module: Combines photodetectors, LEDs, and an optical AFE, reducing the need for additional components.
2. Ultra-Low Power: Optimized for low power consumption to extend battery life in wearable devices.
3. High Sensitivity: Offers high signal-to-noise ratio for accurate readings even in low-light conditions.
4. Compact Size: Its small form factor is ideal for space-constrained applications such as fitness trackers and smartwatches.
5. Flexible Operation: Programmable sample rates and LED current settings for customized configurations.
6. I²C Interface: Enables easy communication with microcontrollers and other digital systems.
7. Ambient Light Cancellation: Reduces noise from external light sources, enhancing accuracy.
8. Multiple Applications: Suitable for wrist, finger, or ear-based measurement devices.
These features make the MAXM86161EFD+T a versatile solution for health monitoring in various wearable technology applications.
Package
The MAXM86161EFD+T is available in a compact package type, specifically a 2.9mm x 4.3mm x 1.4mm, 22-pin optical module. It integrates LEDs, a photodetector, and an optical AFE in a single package designed for ultra-low-power operation and small size, making it suitable for wearable applications.
Pinout
The MAXM86161EFD+T is a high-performance, low-power optical sensor module designed for wearable applications, particularly for heart-rate and SpO2 monitoring. It is a compact, integrated module consisting of photodetectors, analog-to-digital converters, and a microcontroller interface.
The module features a 9-pin land grid array (LGA) package. The pins include connections for power supply, ground, digital interface, and control signals. Key functions performed by the module include optical data acquisition, signal processing, and communication with a host microcontroller through its I²C digital interface, which allows for configurable operation and data transfer.
This sensor module efficiently captures photoplethysmography (PPG) signals, crucial for monitoring heart rate and blood oxygen levels, with low power consumption, making it ideal for battery-operated devices.
The module features a 9-pin land grid array (LGA) package. The pins include connections for power supply, ground, digital interface, and control signals. Key functions performed by the module include optical data acquisition, signal processing, and communication with a host microcontroller through its I²C digital interface, which allows for configurable operation and data transfer.
This sensor module efficiently captures photoplethysmography (PPG) signals, crucial for monitoring heart rate and blood oxygen levels, with low power consumption, making it ideal for battery-operated devices.
Manufacturer
The MAXM86161EFD+T is manufactured by Analog Devices, Inc., a company that specializes in the design and production of a wide range of semiconductor products, including integrated circuits used in analog, mixed-signal, and digital signal processing. Analog Devices serves various sectors, including industrial, automotive, consumer electronics, and healthcare, providing solutions for sensing, measuring, and interpreting physical phenomena.
Application
The MAXM86161EFD+T is a low-power, optical pulse oximeter and heart-rate sensor module. It is commonly used in wearable devices, such as fitness trackers and smartwatches, for monitoring heart rate, blood oxygen levels, and other vital signs. Additionally, it can be applied in clinical settings for patient monitoring and telemedicine solutions. Its compact size and energy efficiency make it suitable for continuous monitoring applications in portable health and wellness devices.
Equivalent
The MAXM86161EFD+T is a pulse oximeter and heart-rate sensor module. Equivalent products include the AMS TMD3725, Silicon Labs' Si1144-M01-GM, and Texas Instruments' AFE4400. While these are similar in terms of functionality, be sure to verify compatibility based on specific features, size, power requirements, and data output formats for your application.
船舶
運輸管道我們
通過DHL、FedEx、TNT、UPS或您選擇的任何其他貨運代理提供全球運輸服務。
運費參攷(DHL/FedEx):
動態主要裝載: 運費從25美元到45美元(0.5公斤)不等,預計交貨時間為2-5個工作日。
聯邦快遞: 運費從25美元到40美元(0.5公斤)不等,預計交貨時間為3-7個工作日。
不斷電供應系統: 運費從25美元到45美元(0.5公斤)不等,預計交貨時間為3-7個工作日。
三硝基甲苯: 運費從25美元到65美元(0.5公斤)不等,預計交貨時間為3-7個工作日。
增强型短消息: 運費從30美元到50美元(0.5公斤)不等,預計交貨時間為7-15個工作日。
掛號: 運費為2-4美元(0.1公斤),預計交貨時間為5-20個工作日。
支付
Payment Methods
付款條件為100%預付。
現時,我們只接受以下付款方式:
1. 貝寶
2. 信用卡/借記卡
3. 電匯
類似的
-
MX25R8035FM1IL0
Macronix
-
MX29F400CBTI-70G
Macronix
-
MX25V5126FM1I
Macronix
-
MX25V2033FM1I
Macronix
-
MX25R3235FZNIL0
Macronix
-
MX25L8035EM2I-10G
Macronix
-
MX25R6435FBDIL0
Macronix
-
MX25L25673GMI-10G
Macronix
-
MX25L2006EM1I-12G
Macronix
-
MX25L6433FM2I-08G
Macronix
-
MX25U6435FM2I-10G
Macronix
-
MX25L25645GXDI-08..
Macronix